Vedere la pagina 28
Registers 19
I/O Address Read Write
Base + 0x00 Scan Interval Counter Scan Interval Counter
Base + 0x04 Sample Interval Counter Sample Interval Counter
Base + 0x08 Scan Counter Scan Counter
Base + 0x0C DIV Counter DIV Counter
Base + 0x10 Delay1 Counter Delay1 Counter
Base + 0x14 M Counter M Counter
Base + 0x18 GP Counter/Timer 0 GP Counter/Timer 0
Base + 0x1C X X
Base + 0x20 X GP Counter/Timer Control Reg
Base + 0x24 A/D FIFO Data Reg
Config. Channel Gain Queue
Reg..
Base + 0x28 A/D and FIFO Status Reg. A/D and FIFO Control Reg.
Base + 0x2C X X
Base + 0x30 Digital IN Reg.(Dout) Digital OUT Reg.
Base + 0x34 X A/D Trigger Mode Reg.
Base + 0x38 Interrupt Reason Reg. Interrupt Control Reg.
Table 2. I/O Port Address