ADLINK Technology PCI-8136M Guida Utente Pagina 79

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 107
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 78
Motion Libra 71
Visual Basic 5.0 or higher
B_8136_D_Output(ByVal CardNo As Integer, ByVal Channe As
Integer, ByVal Control As Integer) As Integer
B_8136_D_Input(ByVal CardNo As Integer, ByVal Channel As
Integer, Control As Integer) As Integer
B_8136_D_OutputA (ByVal CardNo As Integer, ByVal Value As
Integer) As Integer
B_8136_D_InputA(ByVal CardNo As Integer, Value As Long) As
Integer
@ Argument
CardNo: card number designated to set (Range 0 ~ 3)
Channel: channel number designated to set (Range 0 ~ 6)
Control: control value for the designated channel (Range 0 ~ 1)
Value: control value for all digital output (Range 0 ~ 0x7f )
Control: return value for designated channel (Range 0 ~ 1)
Value: return value for all digital input (Range 0 ~ 0x7ffff)
@ Return Code
ERR_RangeError
ERR_NoError
Vedere la pagina 78
1 2 ... 74 75 76 77 78 79 80 81 82 83 84 ... 106 107

Commenti su questo manuale

Nessun commento